L830 Series Isolation Transformers-60Hz
 

Application

Integro FAA Approved Series Isolation Transformers are used to isolate high operating voltage for constant current airfield lights in a series circuit. They are encapsulated and designed to operate efficiently while submerged in water. They are approved to operate between -55 C and + 65 C and can be installed above ground, in metal cans or direct buried.

Where They are Used

Integro Series Isolation Transformers are installed at most major airports in the United States and Mexico, as well as in many countries in South America, Europe, Asia and Africa. Our American made Series Isolation Transformers are also preferred at many military airports in the United States.

Approvals and Testing

Integro Series Isolation Transformers are approved to the FAA L-830 specification and are certified by ITS Testing Labs to FAA Advisory Circular 150/5345-47. All Integro Transformers undergo 100% Quality Testing which includes visual inspection, ratio testing, heat testing and HIPOT testing after heating and 12 hour soaking.

Click here to to view Certifications

Design

Integro Series Isolation Transformers are wound for 6.6 and 20 Amp primary circuit applications. They are encapsulated in thermoplastic rubber for superior durability and dielectric strength and are manufactured with 2 primary and 1 secondary FAA L-823 listed leads.

 FAA
Designation
 
Integro
Part #
 
Description Pri/Sec
Amps
 
Design
Frequency (Hz)
 
Weight
(in lbs.)
 
L830-16 11717 10/15W 6.6/6.6 60 3.86
L830-17 11729 20/25W 6.6/6.6 60 4.33
L830-1 11680 30/45W 6.6/6.6 60 4.35
L830-2 11681 30/45W 20/6.6 60 4.22
L830-3 11682 65W 6.6/6.6 60 4.73
L830-4 11683 100W 6.6/6.6 60 8.36
L830-5 11684 100W 20/6.6 60 8.56
L830-18 11730 150W 6.6/6.6 60 8.62
L830-19 11731 150W 20/6.6 60 8.60
FAA
Designation
Integro
Part #
DescriptionPri/Sec
Amps
Design
Frequency (Hz)
Weight
(in lbs.)
L830-6 11685 200W 6.6/6.6 60 10.40
L830-7 11686 200W 20/6.6 60 10.54
L830-10 11736 300W 6.6/6.6 60 10.91
L830-11 11760 300W 20/6.6 60 10.88
L830-9 11516 300W 20/20 60 21.80
L830-14 11517 500W 6.6/6.6 60 18.50
L830-15 11529 500W 20/6.6 60 15.77
L830-13 11506 500W 20/20 60 15.90

The leads are:

  • Style 2- Male Primary Lead on 8/1 cable, 24" long.
  • Style 9- Female Primary Lead on 8/1 cable, 24" long
    (Both leads are rated 25 Amps and 5,000 Volts).
  • Style 8- Female Secondary Lead on 12/2 cable, (rated 20 Amps and 600 Volts), 48" long.